Clinical Trial: Ultrasound Biomicroscopic Analysis of Cionni Ring and In-the-bag IOL Implantation for Subluxated Lenses

Study Status: Completed
Recruit Status: Completed
Study Type: Observational

Official Title: Ultrasound Biomicroscopic Analysis of Cionni Ring and In-the-bag IOL Implantation for Subluxated Lenses

Brief Summary: To report the Ultrasound Biomicroscopic findings following Cionni Ring bag fixation and in-the-bag IOL Implantation. To assess the relationship of the Bag and Cionni ring positioning in relation to surrounding ocular structures, in pediatric eyes

Detailed Summary: Cionni ring fixation of the capsular bag in conjunction with placement of an IOL has been found to be safe and effective compared with other current alternatives, even given the exceptionally high difficulty levels and complexity of these cases, in both adult and pediatric eyes. One limitation of techniques requiring trans-scleral suturing is that the suture cannot always be passed under adequate visualization, and, once the knot is secured, the exact position of the Cionni ring cannot always be accurately localized. Analysis of Cionni ring position with respect to the IOL and iris is important, as faulty placement of the ring or IOL can lead to complications which can threaten vision, especially in children with a high predisposition towards postoperative adverse events. Unfortunately, pupillary dilatation and slit-lamp examination may not always be adequate to assess the Cionni ring or the eyelet position, as it occupies the peripheral section of the capsular bag. UBM has been shown to be accurate and reproducible in examining the haptic position in relation to the sulcus and ciliary body, anterior chamber depth (ACD), vitreous incarceration, focal iris abnormalities, angle anatomy, and relationship of the iris to the lens (straight or tilted). This study aims to provide information on UBM findings following Cionni ring implantation in pediatric eyes for non-traumatic subluxation of the crystalline lens.
Sponsor: Iladevi Cataract and IOL Research Center

Current Primary Outcome: Ultrasound Biomicroscopic Measurement of Anterior Chamber Depth, Cionni Ring Position, distance from the posterior surface of iris and ciliary body region [ Time Frame: 6 months postoperative ]

To Measure in millimeters, the anterior chamber depth, the distance of cionni ring from posterior surface of iris, the distance of cionni ring from the ciliary body region


Original Primary Outcome: Same as current

Current Secondary Outcome:

Original Secondary Outcome:

Information By: Iladevi Cataract and IOL Research Center

Dates:
Date Received: May 24, 2016
Date Started: January 2014
Date Completion:
Last Updated: June 2, 2016
Last Verified: May 2016