Clinical Trial: The Development and Clinical Verification of Intelligent Rehabilitation System for Leg Length Discrepancy Patients

Study Status: Not yet recruiting
Recruit Status: Not yet recruiting
Study Type: Interventional

Official Title:

Brief Summary:

A structural leg length discrepancy (SLLD) is a common clinical problem. Its prevalence has been estimated at 40-70%. Those who have been suffered from limping for a long time may lead to follow-up low back pain and lower limb musculoskeletal disorders. Although lower limb triple view of x-ray is considered to be the current technique for determining LLD, it is costly and time consuming that not every hospital can afford it, and in case of radiograph, the patient is exposed to radiation. Therefore, it is necessary to develop a rapid clinical assessment method by gathering exterior parameters to build up a Regression model for measuring the discrepancy and determining LLD accurately.

While using shoe lifts to correct discrepancy is the easiest conservative intervention for LLD, there are still many controversies on how much height should be added clinically and academically. The optimal height should be added depends on feedbacks from users and gait performance. The best gait performance can be measured from kinematic performance of center mass of body during walking. Therefore, this project wants to compare treatment responses between two kinds of shoe lift height correction methods for LLD: given 80% discrepancy in shoe lift height correction through triple view of x-ray and given optimal shoe lift height correction through analyzing kinematic performance of center mass of body.


Detailed Summary:
Sponsor: Taipei Veterans General Hospital, Taiwan

Current Primary Outcome: Visual analogue scale, VAS [ Time Frame: Changes from baseline in VAS for six month continually ]

Pain fields of every participant in two groups will be recorded by APP every day for six month continually. The pain fields include:bilateral cervical, trunk, upper limb, lower limb, and foot regions, totally 10 regions.

The score of each region is determined by measuring the distance (mm) on the 10-cm line between the "no pain" anchor and the patient's mark, providing a range of scores from 0-100. A higher score indicates greater pain intensity. The total score may range from 0-1000.



Original Primary Outcome: Same as current

Current Secondary Outcome:

  • Degree of comfort [ Time Frame: Changes from baseline in comfort scale for six month continually ]
    Degree of comfort at foot site in two groups will be recorded by APP every day for six month continually. The score ranges from 0-10. A higher score indicates greater comfort.
  • areas of pain (cm^2) [ Time Frame: Changes from baseline in areas of pain one time per week for six month ]
    Areas of pain in two groups will be calculated and recorded by APP. The pain fields include:bilateral cervical, trunk, upper limb, lower limb, and foot regions, totally 10 regions. The APP will give participants figures of every region. Each region will be filled with grids. Participants need to select specific grids, according to how many areas pain covers.
  • spatio-temporal parameters of gait [ Time Frame: Changes from baseline in spatio-temporal parameters of gait after intervention immediately and at 4, 8, 12, 24 weeks ]
    GAITRite Walkway, CIR Systems, Havertown, PA, USA. The GaitRITE system was developed in response to the need for an objective way to quantify gait and ambulatory status. The GAITRite System measures spatio-temporal parameters of gait such as cadence, step length, step width, velocity, and toe-out angle, providing clinically relevant information that is useful in devising treatment plans and evaluating treatment outcomes. The system tracks parameters over time and can be used to generate progress and status reports.
  • three dimensional changing joint angles and trunk sway during walking [ Time Frame: Changes from baseline in three dimensional joint angles between two segments and trunk sway during walking after intervention immediately and at 4, 8, 12, 24 week ]
    myoMOTION, Noraxon USA Inc., Scottsdale, AZ, USA. Wireless and portable 3D Kinematic System reveals what's unnoticeable to the naked eye, from small angular displacements to major movement pattern compensations. It contains 13 sensors fixed at bilateral dorsal side of foot, anterior medial side of tibia, lower quadrant of quadriceps, T12/L1, C7, lateral and longitudinal side of upper arm below the trapezius muscle belly, distal part of forearm and sacrum for measuring three dimensional joint angles between two segments and trunk sway during walking.
  • muscle activity [ Time Frame: Changes from baseline in muscle activity after intervention immediately and at 4, 8, 12, 24 weeks ]
    Free EMG 300, BTS Bioengineering, Milan, Italy. BTS FREEEMG 300A is a wireless synchromyography device for dynamic muscular activity analysis. It contains eight channels for detecting muscle activity, including bilateral gluteus medius, vastus lateralis, plantar flexor, and anterior tibialis.
  • plantar force (kgw) [ Time Frame: Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weeks ]
    wireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measureheel, medial forefoot, metatarsal head and hallux plantar force. The more even value of both sides indicates the better correction.
  • plantar pressure (kgw/cm^2) [ Time Frame: Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weeks ]
    wireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measure heel, medial forefoot, metatarsal head and hallux plantar pressure.The more even value of both sides indicates the better correction.
  • contact area (cm^2) [ Time Frame: Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weeks ]
    wireless F-Scan, Tekscan Inc., Boston, MA, USA. The F-Scan system provides dynamic pressure, force and timing information for foot function and gait analysis. Its pressure sensing film will be put between feet and shoe lifts to measure contact area of region of interest. The value will be further calculated for determining whether the foot pronation/supination has been corrected.
  • Energy expenditure (Joule) [ Time Frame: Changes from baseline in plantar force and pressure after intervention immediately and at 4, 8, 12, 24 weeks ]
    iPod Touch, Apple Inc., Cupertino, CA, USA. It will be fixed at lumbar-sacrum junction to measure three-dimensional instantaneous linear acceleration of center mass of body, and further to analyze kinematic performance by calculating three dimensional thrust power and thrust energy. The less energy expends, the better kinematic performance of center mass of body displays.


Original Secondary Outcome: Same as current

Information By: Taipei Veterans General Hospital, Taiwan

Dates:
Date Received: April 1, 2016
Date Started: May 2016
Date Completion:
Last Updated: June 2, 2016
Last Verified: January 2016