Clinical Trial: A Biomechanical Assessment of the AST Stabilimax BAR Using Radiostereometric Analysis (RSA)

Study Status: Withdrawn
Recruit Status: Withdrawn
Study Type: Observational

Official Title: A Biomechanical Assessment of the AST Stabilimax BAR Using Radiostereometric Analysis (RSA)

Brief Summary: Assessment of segmental spine motion has been and continues to be, a difficult clinical problem. Errors of up to 10 degrees for simple measurements of flexion, extension and side bending have been recorded using conventional radiographs (xrays.) These errors are usually associated with the inability to acquire three-dimensional positions and inaccurate reference points. It has, therefore, been extremely difficult to measure small changes in vertebral alignment, which may prove to be an early, clinically significant, indicator of potential problems. Radiostereometric Analysis, or RSA, is an accurate in vivo measurement technique using two simultaneous radiographs. It provides researchers with three dimensional motion analyses to look not only at routine flexion/extension, but also other rotational and translational changes. The measurement accuracy offered by this technique far exceeds the manual techniques currently used. The purpose of this study is to assess the amount of motion in the lumbar spine in patients with the AST Stabilimax BAR. The AST Stabilimax BAR is designed to allow for motion in the spine while providing the necessary stability to the spinal segment. The amount and degree of this motion is currently unknown clinically. By using tantalum bead markers placed in the spine at the time of the surgery, RSA analysis can determine the amount and degree of motion of the implanted construct. Two questions will be examined with this data: 1) what is the amount of sagittal and coronal plane motion that occurs in vivo with the AST Stabilimax BAR system? and 2) will this change over the 2 year time frame for this study?

Detailed Summary:

Radiostereometric Analysis, or RSA, is an accurate in vivo measurement technique using two simultaneous radiographs. It provides researchers with three dimensional motion analyses to look not only at routine flexion/extension, but also other rotational and translational changes. The measurement accuracy offered by this technique far exceeds the manual techniques currently used. Utilization of the RSA technology at the IHP and the United States is in its infancy. The investigators have placed much effort over the past 2-3 years to put the necessary dedicated resources and personnel in place. This has been a collaborative effort between the Department of Orthopedic Surgery and the Imaging Core at IHP. Preliminary work on the accuracy, reliability, and surgical planning for use of RSA has been completed and presented at national conferences.

The purpose of this study is to assess the amount of motion in the lumbar spine in patients with the AST Stabilimax BAR. The AST Stabilimax BAR is designed to allow for motion in the spine while providing the necessary stability to the spinal segment. The amount and degree of this motion is currently unknown clinically, but has been biomechanically tested in vitro. By using tantalum bead markers placed in the spine at the time of the surgery, RSA analysis can determine the amount and degree of motion the implant provides. Two questions will be examined with this data: 1) what is the amount of sagittal and coronal plane motion that occurs in vivo with the AST Stabilimax BAR system? and 2) will this change over the 2 year time frame for this study?


Sponsor: State University of New York - Upstate Medical University

Current Primary Outcome:

Original Primary Outcome:

Current Secondary Outcome:

Original Secondary Outcome:

Information By: State University of New York - Upstate Medical University

Dates:
Date Received: March 4, 2008
Date Started: October 2006
Date Completion:
Last Updated: May 22, 2015
Last Verified: May 2015