Clinical Trial: The Effect of Hydrodynamic Parameters on Corneal Endothelial Cell Loss After Phacoemulsification

Study Status: Completed
Recruit Status: Completed
Study Type: Interventional

Official Title: The Effect of Hydrodynamic Parameters on Corneal Endothelial Cell Loss After Phacoemulsification

Brief Summary: The purpose of this study is to compare two surgical techniques (high vacuum and low vacuum) on corneal endothelium after phacoemulsification.

Detailed Summary:

Patients aged 50 to 70 years old with moderate lens opacities (nuclear sclerosis of 3+) were included. The exclusion criteria were: 1-previous corneal pathology (dystrophic or degenerative such as Fuchs' endothelial dystrophy or advanced trachoma), 2- pseudoexfoliation syndrome (PEX), 3- history of intra ocular surgery, 4- glaucoma or ocular hypertension, 5- eyes with a history of anterior uveitis, 6- diabetes mellitus, 7- anterior chamber depth (ACD) less than 2.5 mm or more than 4 mm, 8- axial length less than 21 mm or more than 25 mm, 9- density of endothelial cells less than 1500 cells per mm2, 10- polymegatism (CV > 0.4), 11- keratometric astigmatism more than 1.5 Diopters (D), 12- history of contact lens usage, 13- Intra-operative complications (posterior capsule rupture with or without vitreous loss), 14- postoperative uveitis, 15- postoperative surgical wound leakage, 16- deep-set eye, and 17- size of dilated pupil less than 6 mm. Nucleus density was evaluated using the LOCS III classification system Patients were divided in 2 groups randomly: Group 1 included those candidates for phacoemulsification using high hydrodynamic parameter: 400 mmHg vacuum and 40 ml/min flow rate (high vacuum technique) whereas group 2 consisted of patients who underwent phacoemulsification using low hydrodynamic parameters: 200 mmHg vacuum and 20 ml/min flow rate (low vacuum technique). All surgeries were performed by one surgeon using stop and chop technique with sovereign (white star technology) (AMO, USA). During sculpting stage, vacuum was 40mmHg and flow rate is 20ml/min, in both groups. Irrigation aspiration of cortical material and viscoelastic were bimanually and semi automatically performed with flow rate of 30ml/min.

Total ultrasound power and total volume of BSS in both groups were measured. Pachymetry, endothelial cell density, polymegathism, before and 1, 6 and 12 weeks
Sponsor: Shahid Beheshti University of Medical Sciences

Current Primary Outcome: Total ultrasound energy dissipated to the eye, total infused fluid, Endothelial cell loss [ Time Frame: All patients were examined on postoperative day 1 and weeks 1, 6 and 12. ]

Original Primary Outcome:

Current Secondary Outcome:

Original Secondary Outcome:

Information By: Shahid Beheshti University of Medical Sciences

Dates:
Date Received: August 31, 2006
Date Started: March 2007
Date Completion:
Last Updated: December 24, 2009
Last Verified: October 2008