Clinical Trial: The Contact-CTI Study: Use of Tissue Contact Data to Guide Atrial Flutter Ablation

Study Status: Active, not recruiting
Recruit Status: Unknown status
Study Type: Interventional

Official Title: The Contact-CTI Study - Does Assessment of Tissue Contact During Ablation of Atrial Flutter Improve Outcomes?

Brief Summary:

This study will be a single blind prospective randomised control trial in patients undergoing ablation for the treatment of typical atrial flutter, with the aim of investigating the benefit of a new impedance-based computer software application which measures tissue contact between the ablation catheter and the inside of the heart.

The investigators hope to demonstrate that the use of this tissue contact information reduces ablation time, Xray time, and procedure time required to complete the procedure successfully. Study participants will be randomly assigned to undergo their procedure with or without this contact data displayed for the doctor performing the ablation to see. The acute procedural endpoint of ablation is successful conduction block across the cavotricuspid isthmus of the right atrium. If the outcome of this study is positive, it will have a significant beneficial impact on this procedure, reducing procedure length, patient discomfort, and potentially reducing risk for the patient, recurrent arrythmia symptoms, and the need for repeat procedures later on.


Detailed Summary: Patients in this study will be de novo cases of atrial flutter ablation, and they will be randomised to ablation using tissue contact data provided by the St. Jude medical ECI technology (active arm), or standard ablation as per physician practice, without the use of contact data to guide ablation (control arm). The endpoint measures will include RF ablation time, procedure time, time to achieving cavotricuspid isthmus block, the need for "touch up" ablation to achieve conduction block, the recurrence rate of isthmus conduction on isuprel infusion at 20 minutes post-isolation, and clinical recurrence of atrial flutter post-operatively.
Sponsor: Oxford University Hospitals NHS Trust

Current Primary Outcome: The primary outcome measure is the mean ablation time required to achieve the acute procedural endpoint of cavotricuspid isthmus conduction block [ Time Frame: immediate (intra-procedural) ]

Original Primary Outcome: Same as current

Current Secondary Outcome:

Original Secondary Outcome:

Information By: Oxford University Hospitals NHS Trust

Dates:
Date Received: May 9, 2012
Date Started: January 2012
Date Completion: December 2012
Last Updated: May 10, 2012
Last Verified: May 2012